Osram PrevaLED Core Z2 Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
25
7. Norms and standards
NORMS AND STANDARDS
7.1. Norms and standards for PrevaLED
®
LED modules and light engines
PrevaLED
®
Core Z2 complies with the following standards:
Zhaga-specifi cation book 3: Spotlight systems with separate
electronic control gear
According to the EC declarations (European directive: 2006/95/EC, European
directive: 2004/108/EC), PrevaLED
®
Core Z2 complies with the following norms:
Safety of LED modules: IEC 62031
Photobiological safety: IEC/TR 62471-2 (typenabhängig)
Electromagnetic compatibility: DIN EN 55015
DIN EN 61547
DIN EN 61000-3-2
DIN EN 61000-3-3
Ingress protection: IP 20
Vibration, shocks, tensile strength: IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-21
7.2. Norms and standards for control gears
Safety: IEC 61347-1, IEC 61347-2-13
Performance: IEC 62384
Radio interference: EN 55015 (A1:2007, A2:2009)
Harmonic content: IEC 61000-3-3:2008
Immunity: IEC 61547:2009
Temperature range: See corresponding value within the datasheet
Galvanic insulation between
primary and secondary side: 3 kV
rms
No-load proof: Yes
Short circuit proof: Yes
Overload protection: Automatic shutoff, reversible
Overheating protection: Automatic shutoff, reversible
Connection, primary: For OTp 15 HD: screw-terminals
For OTp 35 HD and OTp 45 HD: push-in terminals
Cross section, primary: 0.5 mm
2
–1.5 mm
2
Connection, secondary: 5-pin connector, for use with cable kit
Cross section, secondary: Only for use with special cable kit
Dimensions (L x W x H): 123 x 79 x 33 mm for all OTp 35 and all OTp 45
109 x 50 x 35 mm for OTp 15 HD
Approvals:
0 i
]
For test and certifi cation measurements,
a mains voltage of 230 is recommended.
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27

Comentarios a estos manuales

Sin comentarios